Tuesday, March 3, 2015

KODE ERROR AC MERK TCL

KODE ERROR AC MERK TCL



TCL Error Code
Failure type = In and out communication failure
LED CODE = RUN,TIMER –both winking
DIGITAL LED CODE = E0
Failure type = Outdoor communication failure
LED CODE = RUN,TIMER –both winking
DIGITAL LED CODE = EC
Failure type = Outdoor sensor
LED CODE = RUN-1 time/8s
DIGITAL LED CODE = E1
Failure type = Indoor coil temperature sensor
LED CODE = RUN-2 times/8s
DIGITAL LED CODE = E2
Failure type = Outdoor coil temperature sensor
LED CODE = RUN-3 times/8s
DIGITAL LED CODE = E3
Failure type = System abnormity
LED CODE = RUN-4 times /8s
DIGITAL LED CODE = E4
Failure type = Type mismatch
LED CODE = RUN-5 times /8s
DIGITAL LED CODE = E5
Failure type = Indoor fan motor
LED CODE = RUN-6 times /8s
DIGITAL LED CODE = E6
Failure type = Outdoor temperature sensor
LED CODE = RUN-7 times /8s
DIGITAL LED CODE = E7
Failure type = Discharge temperature sensor
LED CODE = RUN-8 times /8s
DIGITAL LED CODE = E8
Failure type = Invert module abnormity
LED CODE = RUN-9 times /8s
DIGITAL LED CODE = E9
Failure type = Outdoor fan motor (DC)
LED CODE = RUN-10 times /8s
DIGITAL LED CODE = EF
Failure type = Current sensor
LED CODE = RUN--11 times /8s
DIGITAL LED CODE = EA
Failure type = EEPROM failure
LED CODE = RUN-12 times /8s
DIGITAL LED CODE = EE
Failure type = Top of compressor temperature switch
LED CODE = RUN-13 times /8s
DIGITAL LED CODE = EP
Failure type = Voltage sensor
LED CODE = RUN-14 times /8s
DIGITAL LED CODE = EU
Protection display code list:
Protection type = higher or lower voltage
LED CODE = RUN-winking,TIMER-1 time/8s
DIGITAL LED CODE = P1
Protection type = Over current
LED CODE = RUN- winking,TIMER-2 times /8s
DIGITAL LED CODE = P2
Protection type = Discharge temperature
LED CODE = RUN- winking,TIMER-4 times /8s
DIGITAL LED CODE = P4
Protection type = Over cooling in cooling mode
LED CODE = RUN-light,TIMER-5 times /8s
DIGITAL LED CODE = P5
Protection type = Over heating in cooling mode
LED CODE = RUN- light,TIMER-6 times /8s
DIGITAL LED CODE = P6
Protection type = Over heating in heating mode
LED CODE = RUN- light,TIMER-7 times /8s
DIGITAL LED CODE = P7
Protection type = Outdoor temperature too high or low
LED CODE = RUN- light,TIMER-8 times /8s
DIGITAL LED CODE = P8
Protection type = Drive protection(Overload)
LED CODE = RUN- winking,TIMER-9 times/8s
DIGITAL LED CODE = P9
Protection type = Module self protection
LED CODE = RUN- winking,TIMER-10 times/8s
DIGITAL LED CODE = P0
Outdoor failure display
There is a LED on outdoor power board, when compressor is running; it is normally light;
when no feedback of signal to power board from compressor, it will wink by lighting 1s and
going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go
out 3s for a cycle to indicate failures. The failure list is the follow:
Wink time = 1
Failure = IPM protection
Wink time = 2
Failure = higher or lower voltage
Wink time = 3
Failure = Over current
Wink time = 4
Failure = Discharge temperature too high
Wink time = 5
Failure = Outdoor coil temperature too high
Wink time = 6
Failure = Drive abnormity
Wink time = 7
Failure = Communication abnormity with indoor unit
Wink time = 8
Failure = Compressor over heat (switch on top of compressor)
Wink time = 9
Failure = Outdoor air temperature sensor failure
Wink time = 10
Failure = Outdoor coil temperature sensor failure
Wink time = 11
Failure = Outdoor discharge pipe temperature sensor failure
Wink time = 12
Failure = Voltage sensor failure
Wink time = 13
Failure = Current sensor failure
Wink time = 14
Failure = IPM abnormity
Wink time = 15
Failure = Outdoor communication abnormity
Wink time = 16
Failure = DC fan motor no feedback
Wink time = 17
Failure = defrosting



SILAKAN DI TRANSLATE KE https://translate.google.com/