Daikin Fault Basic Fault Codes
A0 Indoor error of external protective device
A1 Indoor printed Circuit board
A3 Indoor malfunction of drain level control system
A5 Indoor freeze up prevention
A6 Indoor fan motor lock/overload
A7 Indoor malfunction of swing motor flap
A9 Indoor malfunction of EEV
AF Indoor drain level above limit
AJ Indoor malfunction of capacity set device
C3 Indoor malfunction of drain thermister
C4 Indoor malfunction of liquid pipe thermister
C5 Indoor malfunction of gas pipe thermister
C7 Indoor lower Louvre limit switch/motor
C9 Indoor malfunction of air thermister
CC Indoor malfunction of moisture sensor
CA Indoor malfunction of discharge air thermistor
CJ Indoor malfunction of remote control thermistor
CE Indoor malfunction of radiant heat sensor
E0 Outdoor activation of outdoor safety device
E1 Outdoor printed circuit board defect
E3 Outdoor activation of high pressure switch
E4 Outdoor activation of low pressure switch
E5 Outdoor activation of compressor over heat protection or motor lock
E6 Outdoor compressor start up, lock or over current
E7 Outdoor fan motor lock, overload
E8 Outdoor inverter input over current
E9 Outdoor malfunction of EEV
EA Outdoor four way valve defect
F3 Outdoor abnormal discharge pipe temperature
F6 Outdoor refrigerant overcharged
FC Outdoor low pressure drop
H3 Outdoor high pressure drop defect
H4 Outdoor low pressure switch defect ( http://angtek.blogspot.com )
H6 Outdoor motor position detection sensor error
H7 Outdoor fan motor position sensor error
H8 Outdoor Current transformer error
H9 Outdoor malfunction of air thermistor
J1 Outdoor malfunction of pressure sensor
J2 Outdoor current sensor malfunction
J3 Outdoor malfunction of discharge pipe thermister
J4 Outdoor low pressure saturation thermistor
J5 Outdoor malfunction of suction pipe thermistor
J6 Outdoor malfunction of heat exchange thremistor
J7 Outdoor malfunction of heat exchanger liquid thermistor
J8 Outdoor malfunction of liquid pipe thermistor
J9 Outdoor malfunction of gas pipe thermistor
JA Outdoor malfunction of discharge pipe pressure sensor
JC Outdoor malfunction of suction pipe pressure sensor
L0 Outdoor malfunction of inverter
L3 Outdoor malfunction of component box overheat
L4 Outdoor inverter cooling defect
L5 Outdoor compressor motor fault short circuit
L6 Outdoor compressor grounding or short circuit
L7 Outdoor input current
L8 Outdoor Compressor overload, motor lock
LA Outdoor unit malfunction
LC Outdoor transmission between inverter and outdoor unit
P1 outdoor inverter over ripple
P3 Outdoor thermistor abnormality (http://angtek.blogspot.com)
P4 Outdoor power unit humidity sensor malfunction
PJ Outdoor failure of capacity set resistor
U0 System shortage of refrigerant or EEV failure
U1 System negative phase/open phase
U2 System power supply insufficient
U3 System wiring check operation not executed (also check for unit mismatch)
U4 System transmission between indoor and outdoor units
U5 System transmission to remote controller
U6 System malfunction transmission outdoor to BP unit
U7 System transmission between outdoor units (could also be between boards) (http://angtek.blogspot.com)
U8 System transmission between master and slave units
U9 transmission error between indoor and outdoor
UA System excessive number of fan coils
UC Address Duplication of central controllers ( http://angtek.blogspot.com )
UE Transmission error between units
UF refrigeration system not set or connections three and four crossed
UH System error Refrigeration set up
M1 printed circuit board defect
M8 Transmission error between central control units
MA Improper combination of system controllers
MC Address duplicated or wrong settings used
64 VAM Thermistor error indoor unit
65 VAM outdoor thermistor error
6A VAM alarm damper system mechanical or thermistor failure (http://angtek.blogspot.com)
6F VAM remote controller failure
6H VAM malfunction of connector/door switch
94 VAM transmission failure internal ( http://angtek.blogspot.com )
NB : bila lebih jelas di translate ke indonesia translate.google.com/
ebih detilnya lagi tentang air conditioner silakan mampir di blog ini http://angtek.blogspot.com/
dan juga di head office .
jl kebalen kulon 3/19 surabaya
0819-3818-5336
085-235-75805
Subscribe to:
Post Comments (Atom)
This is a much needed guide for air conditioner replacement part. This article serves well in its way. Heating and Cooling Vaughan
ReplyDelete